Karwan Ahmed Raouf
Indian Orthopaedic Research Group
45 years old with segmental fracture of tibia fixed by locked plate ( MIPO ) , comments
Me gusta
Sony Habibur Rahman
Very well done. ..1st. Distal screw appears to be a bit close to the distal fracture site...
Ayer a las 12:31
·
Me gusta
·
1
Rimon Lazar Sliwa
Good job, i agree the screw was near to distal fracture
Ayer a las 12:50
·
Me gusta
·
2
Subhranshu Sekhar Nayak
Well done
Ayer a las 12:53
·
Me gusta
·
1
Shivendra Sinha
skin condition photo please?surgery very good.
Ayer a las 12:55
·
Me gusta
·
1
Rajeev Kant Pandey
excellent...nicely done
Ayer a las 13:06
·
Me gusta
·
1
Sen Balan
Nice
Ayer a las 13:38
·
Me gusta
·
1
Karthikeyan Mani
ETN Could have been better choice, distal # may go for non union as there is no compression at # site besides it is a wedge butterfly fragment
Ayer a las 13:53
·
Me gusta
Karwan Ahmed Raouf
For the 1st distal screw ...it is not inside the fracture site ...better to be close the fracture site
Ayer a las 14:09
·
Me gusta
Karwan Ahmed Raouf
Although just this hole remain locked one that is why i put that
Ayer a las 14:10
·
Me gusta
Tariq A-Fattah
So nice
Ayer a las 14:28
·
Me gusta
Diyar Sulaiman
Nice ..well done
Ayer a las 15:18
·
Me gusta
·
1
Murshid H. Alsaki
The distal screw is close to the # , the next hole was more appropriate even if not locked because you have 2 other locked screws. I think you obligated to open the fracture site for that screw?
Ayer a las 16:26
·
Editado
·
Me gusta
·
1
Karwan Ahmed Raouf
Dear dr
Murshid H. Alsaki
i will follow him .....but i dont think so
Ayer a las 18:04
·
Me gusta
Karwan Ahmed Raouf
Any other think you have dr
Murshid H. Alsaki
?
Ayer a las 18:05
·
Me gusta
Islam Al-rajabi
Well done sir
Ayer a las 18:51
·
Me gusta
Murshid H. Alsaki
You didnot get it , I asked did you opened the fracture site for that screw
Ayer a las 18:51
·
Me gusta
Karwan Ahmed Raouf
No no i didnt opened .....sorry for that
Ayer a las 18:56
·
Me gusta
·
1
Arun Govindasamy
Good reduction. Congrats.
Ayer a las 21:37
·
Me gusta
·
1
Lokesh Bhatia
Reasonably well done, In your next similar case try and avoid going that close to # site, Keep a close follow up of this case if you feel distal # is not progressing well do not hesitate in Revising the things or do timely intervention.(BMP/Bone Marrow etc)
20 horas
·
Me gusta
·
1
Gopal Goel
good job overall .
16 horas
·
Me gusta
Shrikrishna Dhone
in segmental # always IM implant preferred+BG as always one unites ,second does not unite hence always BG must